Laserfiche WebLink
I <br /> <br />I <br />I <br />I <br />I <br />I <br />I <br />! <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />Preliminary Plat Review: Villas at Meadow Point <br />August 20', <br />Page 3 of 5 <br /> <br />A permit from Anoka County will be required for access on tO' CSAH 57. The plat proposes <br />four new single fam/Iy lots with direct access to Alp/ne Dr. It is desirable to minimize the <br /> <br />number of accesses onto municipal state aid streets. Shared driveways or an eyebrow road <br />treatment should be considered. <br /> <br />The duplex lots are proposed to be served by driveway collectors and a private sheet with a <br />cul-de-sac. The driveway collectors and private streets servicing Block 2 are 32 feet wide mud <br />may have on-street parking.. The two temporary dead ends must be designed with t-emp0rarf <br />cul-de-sacs. The private street servicing Block 3 must be minimum of 3.2 feet wide. The <br />private drive serving Block 1 must be equipped .with a turn around.' <br /> <br /> Gradin. a and Drainage: Staff has reviewed· the drainage and grading plan and find the plan <br /> generally acceptable with the following comments: <br /> · A permit from the Lower Rum River Water Management Organization and the IVfPCA <br /> will be required for this development. <br /> · Lots 3 and 4, Block 3 should 'have the lowest floor elevation a minimum of 0.5 feet above <br /> the lowest surrounding grade. Low floor ~ade should be raised to 877.5. <br /> · Rear yard grade around Lots 5 thru I4, Block 2 are flatter that I% and Will need to be <br /> corrected. <br /> · Contours along the west boundary of the plat should be emended for 100 feet beyond the <br /> property line so that the impact on the adjacent property can be determined. <br /> · The contours along the east side of Lots 1-4, Block 2 are incomplete or inadequately <br /> labeled. This area should be clarified. <br /> · Spot elevations need to be provided on the extensions of the building pads: <br /> · The private road elevation in front of Lots 9 and 10, Block I is 882. However, the <br /> garage floor elevation is 880.9. The garage floor.elevation carmot be loWer than the road <br /> elevation. <br /> · The lowest at ~ade elevation adjacent to Lot 11, BlOck 1 is 880, but the lookout <br /> elevation is 877.3. This inconsistency must be corrected. <br /> · The lot tabulations have only been provided for Block 3. The tabulations need to be <br /> provided for the rest of the subdivision. <br /> · The grading plan does not address all of the single family lots along AlPine Dr. please <br /> submit information regarding these lots: . <br /> <br />A revised grading and drainage plan must be provided to the CiTM before you will receive <br />...approval of the grading and drainage plans. <br /> <br />10. Utilities and Water Usage: The dex;.~topment will be served by municipal water and Sanitary <br /> sewer and all utilities must be extended to the end of the plat on all stub streets. Staff has the <br /> fbllowing additional comments: <br /> <br />67 <br /> <br /> <br />