My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 10/29/2026
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2026
>
Agenda - Planning Commission - 10/29/2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2026 1:52:45 PM
Creation date
11/5/2026 1:47:21 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
10/29/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES <br />1.THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND LOCATION <br />OF EXISTING UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. <br />THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATION AS TO <br />TYPE AND LOCATION OF UTILITIES AS NECESSARY TO AVOID DAMAGE TO THESE <br />UTILITIES. <br />2.CALL GOPHER STATE ONE CALL AT LEAST 48 HOURS PRIOR TO ANY EXCAVATIONS <br />FOR EXISTING UTILITIES LOCATIONS. <br />3.THE CONTRACTOR SHALL FIELD VERIFY SIZE, ELEVATION, AND LOCATION OF <br />EXISTING UTILITIES AND NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO THE <br />START OF INSTALLATIONS. <br />4.ALL WORK SHALL BE PERFORMED DURING CITY APPROVED WORKING HOURS. <br />5.PARKING, EQUIPMENT STORAGE OR MATERIAL STORAGE SHALL NOT BE ALLOWED ON <br />PUBLIC STREETS OR WITHIN PUBLIC RIGHT-OF-WAY. <br />6.NOTIFY CITY A MINIMUM OF 48 HOURS PRIOR TO THE COMMENCEMENT OF <br />CONSTRUCTION. <br />7.ALL ELECTRIC, TELEPHONE, AND GAS EXTENSIONS INCLUDING SERVICE LINES SHALL <br />BE CONSTRUCTED TO THE APPROPRIATE UTILITY COMPANY SPECIFICATIONS. ALL <br />UTILITY DISCONNECTIONS SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY <br />COMPANY. <br />8.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING <br />TRAFFIC CONTROL, SUCH AS BARRICADES, WARNING SIGNS, DIRECTIONAL SIGNS, <br />FLAGMEN AND LIGHTS, AS NECESSARY TO CONTROL THE MOVEMENT OF TRAFFIC. <br />EXISTING BITUMINOUS <br />EXISTING CATCH BASIN <br />EXISTING HYDRANT <br />EXISTING WATER MAIN <br />EXISTING GATE VALVE <br />EXISTING CATCH BASIN MANHOLE <br />EXISTING STORM SEWER <br />EXISTING FIBEROPTIC BOX <br />(GUTTERLINE, BITUMINOUS SURFACE, OR GROUND <br />SURFACE UNLESS OTHERWISE INDICATED) <br />920.60 <br />920.99 <br />PROPOSED SPOT ELEVATION <br />EXISTING SPOT ELEVATION <br />PROPOSED SILT FENCES <br />928 PROPOSED CONTOUR <br />EXISTING CONTOUR <br />PROPOSED WATER PIPEEXISTING UNDERGROUND ELECTRICE <br />GE <br />EXISTING SANITARY SEWER <br />PROPOSED SANITARY SEWER PIPEGASEXISTING UNDERGROUND GAS <br />EXISTING LIGHT POLE <br />PROPOSED STORM SEWER PIPE <br />PROPOSED STORM MANHOLE <br />PROPOSED CATCH BASIN <br />EXISTING SANITARY SEWER MANHOLE <br />PROPOSED GATE VALVE <br />PROPOSED DRAINTILE AND CLEAN-OUT <br />EXISTING FLARED-END SECTION <br />EXISTING UNDERGROUND CABLECBL <br />PROPOSED DIRECTION OF DRAINAGE <br />930 <br />4.0% <br />930 <br />WV <br />D <br />PROPOSED INLET PROTECTION <br />EXISTING MISC. MANHOLE <br />S <br />LEGEND <br />AN MPCA NPDES CONSTRUCTION PERMIT IS REQUIRED <br />PRIOR TO THE START OF CONSTRUCTION <br />ALL PERMITS, INCLUDING BUT NOT LIMITED TO <br />PERMITS FROM CITY OF RAMSEY, MNDOT, AND THE <br />MINNESOTA DEPARTMENT OF LABOR AND INDUSTRY, <br />SHALL BE OBTAINED PRIOR TO ORDERING OF <br />MATERIAL AND STARTING OF CONSTRUCTION. NO <br />INSTALLATION OF UTILITIES SHALL BE PERMITTED <br />UNTIL ALL APPLICABLE PERMITS ARE RECEIVED BY <br />CONTRACTOR. INSTALLATION OF UTILITIES SHALL BE <br />CONSTRUCTED TO MINNESOTA DEPARTMENT OF <br />LABOR AND INDUSTRY STANDARDS AND CITY <br />STANDARDS AS IDENTIFIED IN THE PUBLIC <br />WORKS/ENGINEERING STANDARDS. <br />1.SANITARY SEWER MATERIALS SHALL BE: <br />1.1.8" PVC SDR 26 <br />2.FIELD VERIFY SIZE, ELEVATION AND LOCATION OF EXISTING SANITARY SEWER AND <br />NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO ANY INSTALLATIONS. <br />3.INSTALLATIONS SHALL CONFORM TO THE MOST CURRENT VERSION OF THE CEAM <br />STANDARD SPECIFICATIONS. <br />4.CONTRACTOR TO CONTACT CITY ENGINEERING DEPARTMENT AT LEAST 48 HOURS <br />PRIOR TO CONNECTION TO EXISTING PUBLIC SANITARY SEWER. <br />1.WATERMAIN MATERIALS SHALL BE: <br />1.1.6" DIP CLASS 53 <br />2.FIELD VERIFY SIZE, ELEVATION, AND LOCATION OF EXISTING WATERMAIN AND <br />NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO ANY INSTALLATIONS. <br />3.INSTALLATIONS SHALL CONFORM TO THE MOST CURRENT VERSION OF THE CEAM <br />STANDARD SPECIFICATIONS. <br />4.MAINTAIN A MINIMUM OF 7.5 FEET OF COVER OVER ALL WATERMAIN PIPE. <br />5.PROVIDE PREFORMED INSULATION, PPG FOAMGLASS, OR APPROVED EQUAL WHERE <br />SANITARY SEWER OR STORM SEWER CROSSES WITHIN 24" OF WATERMAIN. <br />6.WATERMAIN SHUTOFF REQUIRES A MIN. 48 HOUR NOTICE TO CITY ENGINEERING <br />DEPARTMENT AND ALL AFFECTED PROPERTY OWNERS. <br />SANITARY SEWER NOTES <br />WATERMAIN NOTES <br />868. <br />1 <br />6 <br />868.10 <br />TCCB <br />86 <br />7 <br />. <br />5 <br />1 <br />CB <br />F <br />L <br />867.33 <br />CBFL <br />86 <br />7 <br />. <br />9 <br />4 <br />TC <br />C <br />B <br />8 <br />6 <br />8 <br />. <br />6 <br />2 <br />T <br />C <br />C <br />B <br />868.02 <br />CBFL <br />865 <br />. <br />7 <br />8 <br />CB <br />865 <br />. <br />5 <br />5 <br />TCC <br />B <br />864.94 <br />CBFL <br />866 <br />. <br />6 <br />1 <br />TCC <br />B <br />866.0 <br />6 <br />CBFL <br />8 <br />6 <br />5 <br />. <br />5 <br />3 <br />T <br />C <br />C <br />B <br />864. <br />9 <br />9 <br />CBF <br />L <br />864 <br />. <br />3 <br />1 <br />FES <br />867.66 <br />CBFL <br />87 <br />0 <br />. <br />6 <br />1 <br />TN <br />H <br />X <br />Y <br />Z <br />82 <br />82 <br />64 <br />64 <br />10 <br />0 <br />10 <br />0 <br />NO <br />T <br /> <br />F <br />I <br />E <br />L <br />D <br /> <br />L <br />O <br />C <br />A <br />T <br />E <br />D <br />868.1 <br />ELC-M <br />A <br />R <br />K <br />E <br />R <br />868 <br />. <br />2 <br />ELC <br />- <br />M <br />A <br />R <br />K <br />E <br />R <br />86 <br />6 <br />. <br />4 <br />86 <br />5 <br />. <br />8 <br />86 <br />5 <br />. <br />5 <br />865 <br />. <br />5 <br />4 <br />ELE <br />C <br />- <br />O <br />U <br />T <br />L <br />E <br />T <br />865 <br />. <br />3 <br />5 <br />ELE <br />C <br />- <br />O <br />U <br />T <br />L <br />E <br />T <br />0.3 <br />0.5 <br />UTILITY <br />VAULTS <br />866.85 <br />MHSAN <br />20 <br />PROPOSED <br />BUILDING <br />FFE 867.20 <br />6" <br />D <br />I <br />P <br /> <br />W <br />. <br />M <br />. <br />EX. 32'-8" PVC <br />SDR-26 @ 2.0% <br />EX. 8" PVC PLUG <br />INVERT = 857.87 <br />SAN C.O. <br />RE 866.70 <br />IE 859.13 <br />63' <br />- <br /> <br />8 <br />" <br /> <br />P <br />V <br />C <br /> <br />S <br />A <br />N <br /> <br />@ <br /> <br />2 <br />. <br />0 <br />% <br />EXISTING <br />HYDRANT <br />EX <br />. <br /> <br />8 <br />" <br /> <br />D <br />I <br />P <br /> <br />W <br />. <br />M <br />. <br /> <br />( <br />C <br />L <br />A <br />S <br />S <br /> <br />5 <br />2 <br />) <br />EX <br />. <br /> <br />8 <br />" <br /> <br />P <br />V <br />C <br /> <br />S <br />A <br />N <br />. <br /> <br />S <br />W <br />R <br /> <br />@ <br /> <br />0 <br />. <br />4 <br />0 <br />% <br />EX. 21'-8" DIP (CLASS 52) <br />W/ DIP CAP/PLUG AT END <br />EX. 6" DIP CLASS 53 <br />(PER PLANS PROVIDED <br />BY THE CITY) <br />CONNECT TO EXISTING <br />WATERMAIN W/ 8" x 6" <br />REDUCER <br />TWO (2) 6" - 45° BENDS <br />CONNECT TO EXISTING SANITARY <br />SEWER STUB (APPROX. IE 857.87) <br />EXTEND WATER & SANITARY <br />SERVICES INTO BUILDING <br />AT LOCATION DETERMINED <br />BY OWNER <br />17' - 8" PVC SAN @ 2.0% <br />END IE 859.47 <br />FD CONNECTION <br />8 <br />6 <br />5 <br />. <br />2 <br />9 <br />T <br />C <br />C <br />B <br />864.65 <br />CBFL <br />866.74 <br />CBFL <br />NO <br />R <br />T <br />H <br />1 INCH = 20 FEET <br />HORIZONTAL <br />20 0 10 20 40 <br />(22" x 34") <br />S:\PLOWE\CAD\26PROJ\2268 GATHER (RAMSEY)\2268 CAD\2268 BASE 3.DWG <br />Thursday, October 15, 2026 3:05:45 PM <br />SHEET <br />C3.1 <br />26-2268 <br />R <br />Call before you dig. <br />below.Know what's <br />FA <br />X <br />: <br /> <br />( <br />6 <br />5 <br />1 <br />) <br /> <br />3 <br />6 <br />1 <br />- <br />8 <br />7 <br />0 <br />1 <br />PH <br />O <br />N <br />E <br />: <br /> <br />( <br />6 <br />5 <br />1 <br />) <br /> <br />3 <br />6 <br />1 <br />- <br />8 <br />2 <br />1 <br />0 <br />LI <br />N <br />O <br /> <br />L <br />A <br />K <br />E <br />S <br />, <br /> <br />M <br />N <br /> <br />5 <br />5 <br />0 <br />1 <br />4 <br />67 <br />7 <br />6 <br /> <br />L <br />A <br />K <br />E <br /> <br />D <br />R <br />I <br />V <br />E <br />SU <br />I <br />T <br />E <br /> <br />1 <br />1 <br />0 <br />SI <br />T <br />E <br /> <br />P <br />L <br />A <br />N <br />N <br />I <br />N <br />G <br />& <br />E <br />N <br />G <br />I <br />N <br />E <br />E <br />R <br />I <br />N <br />G <br />PL <br />O <br />W <br />E <br />EN <br />G <br />I <br />N <br />E <br />E <br />R <br />I <br />N <br />G <br />, <br /> <br />I <br />N <br />C <br />. <br />PR <br />E <br />P <br />A <br />R <br />E <br />D <br /> <br />F <br />O <br />R <br />: <br /> <br /> <br />E <br />L <br />E <br />V <br />A <br />T <br />E <br /> <br />H <br />O <br />P <br />E <br />GA <br />T <br />H <br />E <br />R <br />RA <br />M <br />S <br />E <br />Y <br />, <br /> <br />M <br />N <br />MQ <br />A <br />AG <br />CH <br />E <br />C <br />K <br /> <br />B <br />Y <br />: <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br />26 <br />- <br />2 <br />2 <br />6 <br />8 <br />DA <br />T <br />E <br />: <br />JO <br />B <br /> <br />N <br />O <br />: <br />09 <br />/ <br />1 <br />1 <br />/ <br />2 <br />6 <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />DA <br />T <br />E <br />NO <br />. <br />Da <br />t <br />e <br />: <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />L <br />i <br />c <br />e <br />n <br />s <br />e <br /> <br />N <br />o <br />. <br /> <br />4 <br />3 <br />9 <br />6 <br />3 <br />AD <br />A <br />M <br /> <br />G <br />I <br />N <br />K <br />E <br />L <br />10 <br />. <br />1 <br />9 <br />. <br />2 <br />0 <br />2 <br />6 <br />I <br />h <br />e <br />r <br />e <br />b <br />y <br /> <br />c <br />e <br />r <br />t <br />i <br />f <br />y <br /> <br />t <br />h <br />a <br />t <br /> <br />t <br />h <br />i <br />s <br /> <br />p <br />l <br />a <br />n <br /> <br />w <br />a <br />s <br /> <br />p <br />r <br />e <br />p <br />a <br />r <br />e <br />d <br /> <br />b <br />y <br /> <br />m <br />e <br />or <br /> <br />u <br />n <br />d <br />e <br />r <br /> <br />m <br />y <br /> <br />d <br />i <br />r <br />e <br />c <br />t <br /> <br />s <br />u <br />p <br />e <br />r <br />v <br />i <br />s <br />i <br />o <br />n <br /> <br />a <br />n <br />d <br /> <br />t <br />h <br />a <br />t <br /> <br />I <br /> <br />a <br />m <br /> <br />a <br /> <br />d <br />u <br />l <br />y <br />li <br />c <br />e <br />n <br />s <br />e <br />d <br /> <br />p <br />r <br />o <br />f <br />e <br />s <br />s <br />i <br />o <br />n <br />a <br />l <br /> <br />e <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br /> <br />u <br />n <br />d <br />e <br />r <br /> <br />t <br />h <br />e <br /> <br />l <br />a <br />w <br />s <br /> <br />o <br />f <br />th <br />e <br /> <br />S <br />t <br />a <br />t <br />e <br /> <br />o <br />f <br /> <br />M <br />i <br />n <br />n <br />e <br />s <br />o <br />t <br />a <br />. <br />UT <br />I <br />L <br />I <br />T <br />Y <br /> <br />P <br />L <br />A <br />N <br /> <br />- <br /> <br />S <br />A <br />N <br />I <br />T <br />A <br />R <br />Y <br /> <br />& <br />WA <br />T <br />E <br />R <br />M <br />A <br />I <br />N <br />8 7 5 4 3 2 16 <br />CI <br />T <br />Y <br /> <br />R <br />E <br />V <br />I <br />E <br />W <br /> <br /># <br />1 <br />10 <br />. <br />0 <br />6 <br />. <br />2 <br />6 <br />CI <br />T <br />Y <br /> <br />R <br />E <br />V <br />I <br />E <br />W <br /> <br /># <br />2 <br />10 <br />. <br />1 <br />9 <br />. <br />2 <br />6
The URL can be used to link to this page
Your browser does not support the video tag.