Laserfiche WebLink
-132- <br />must be provided, authorizing the proposed utility service work, from the entity holding the <br />existing electric utility easement. Adequate fire protection for the site, including the location of <br />hydrants and a PIV will be reviewed by the Fire Marshal. An engineering estimate is required to <br />determine the financial security that will insure timely installation of improvements, and to cover <br />City inspection services. Also, the City's standard details must be incorporated into the plans as <br />necessary. <br />Setbacks: The required front, rear, and side setbacks for this site are 35 feet, 35 feet, and 20 <br />feet, respectively. The proposed building conforms to these setbacks. Additionally, there is a 20 <br />foot parking lot setback from street right of ways. All proposed setbacks conform to City Code. <br />It should be noted that improvements to Armstrong Boulevard are planned for 2009. The site <br />plan generally is acceptable to these planned, future improvements. The parking lot setback <br />from street right of ways appears to not conform to future improvements. However, since final <br />design of improvements to Armstrong Boulevard have not yet been completed, the setbacks <br />proposed are acceptable. <br />Architectural Standards: City Code requires that all exterior walls shall be a combination of <br />face brick, stucco, glass, or natural stone. The proposed building uses a combination of brick and <br />cast stone with fabric awnings. This generally meets the requirements of architectural standards. <br />The proposed building appears to be 23.5 feet high, which is conformance of the City Code <br />requirement that all buildings must be under sixty -five (65) feet. <br />Waste Storage: City Code requires that all solid waste and refuse receptacles be stored within a <br />completely screened structure or container. The site plan indicates an enclosed dumpster area <br />behind the building on the north side of the parcel. <br />Off- Street Parking Spaces Required: City Code requires one parking space for each 300 <br />square feet of office floor area and one parking space for each 200 square feet of retail area <br />Thirty-five (35) spaces are required to satisfy the parking requirements for the proposed building. <br />The submitted site plans show forty -nine (49) stalls, which meets the number of required spaces. <br />Off Street Parking - Design: In accordance with City Code, all parking and maneuvering areas <br />must be surfaced with bituminous and the perimeter of all pavement must be finished with B6/12 <br />concrete curbing. It appears as if one -way traffic circulation is proposed along the west side of <br />the buildhig; appropriate traffic control signage must be incorporated into the plans. <br />Lighting: The submitted site plan indicates locations of outdoor lighting, but is deficient of light <br />fixture specifications and light drawings. City standards require that the luminaire (light source) <br />must not be visible from beyond the property line. The applicant should submit shop drawings of <br />the lighting fixtures for review and approval by the City Engineer. Lighting should be evaluated <br />to provide adequate illumination at the access points along Riverdale Drive for traffic safety. <br />Signage: All proposed signage will require a permanent sign permit. A sign permit will need to <br />be approved separate from site plan approval. The proposed ground sign adjacent to Highway 10 <br />