Laserfiche WebLink
-312- <br /> <br />Preliminary Plat: <br />August 8, 2003 <br />Page 7 of 9 <br /> · <br /> <br /> · <br /> · <br /> · <br /> · <br /> · <br /> <br />Ramsey Town Center Addition <br /> <br />Invert elevations are to be shown on grading plans. <br />All proposed contours shall be shown. <br />Grading next to adjacent property north of CR 116 not clearly defined <br />Temporary cul de sacs should be shown at the ends of all dead end roads. <br />Provide for overflow for low area in Parcel 41. <br />A maximum of 5:1 slope is required near the NWC on all wetland mitigation <br />sites. <br />Eliminate the potential for short-circuiting the pond on Parcel 39. <br />Label elevations of holding area in Parcel 25, 26, 28, 39, and 50. <br />Provide outlet piping to all holding ponds that are mentioned. <br />21" storm sewer stub is located in middle of building. <br /> <br />Sheet 18 of 83 <br />· Provide invert elevations of all storm sewer outlets to holding parking areas. <br /> Parcel 2,52,20,21. <br />· No street elevations and building elevations on Parcel 27. <br />· Work needs to be .done on the area north of the railroad tracks and east of <br /> Armstrong Boulevard in Parcel 1. There is a- 20' elevation difference between <br /> the road and the water level. There is a trail required on the east side of <br /> Armstrong Boulevard that is not accounted for. <br />· Storm sewer stub is located in middle of Building Parcel 2. <br />· Maximum slop allowable 4:I. <br /> <br />Sheet 19 of 83 <br />· Building elevations must be shown on all building footprints. <br />· Eliminate roads on County Road 116 that are shown as dedicated access. <br />· Clarify the use of Parcel 55 with contour information. <br />· Provide piping or contours for swale through Parcel 37 for outflow to Town <br /> Center Gardens. This outlet should be included in the 1 st phase of development. <br />· There is a low area created by elevations provided on the south parking - 550 feet <br /> east of east Town Center Drive. <br />· Stubs provided to outlets in middle of building locations near Parcel 30 and 38. <br />· Provide invert elevations for holding areas in Parcel 36,38,32,33. <br />· Internal public roads will be necessary for Parcels 33 - 35 due to access <br /> dedications. <br />· Maximum allowable slope is 4:1. <br />· Determine low area that is created by conversional of Ramsey Boulevard are <br /> urban section and install CBs to pick up water. <br /> <br />Sheet 20 of 83 <br />· Maximum allowable slope is 4:1. <br />· Catch basin stub located in middle of building north of Sunwood Drive. <br />· Drainage area 47 and 48 do not coincide with drainage area map. <br />· Proposed contours for Parcel 5 and 62 do not match with contour information on <br /> street. <br /> <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I: <br />I <br />I <br />I <br />I <br /> I <br />I <br /> I <br /> <br /> <br />