Laserfiche WebLink
Review File: Stoney River <br />Sketch Plan and Site Plan Review <br />June 30, 2011 <br />Page 5 of 10 <br />to change from B-2 General Business District to R-3 High Density Residential in the event the proposed <br />amendment is not passed. <br />Building Height: The B-1 District requires a maximum building height of 35 feet (as measured to mean <br />gable height) for all buildings within this district. The proposed building appears to have two stories with <br />a gable/pitched roof. It is unclear of the submitted architectural renderings have a specific scale, so City <br />Staff has not formally calculated building height. It is assumed that the building height is less than 35 <br />feet; however, the developer should provide scaled renderings with the Building Permit to verify actual <br />building height. <br />Maximum Structure Area. The B-1 District requires a maximum structure area of 35% of the lot area. <br />The proposed structure appears to cover approximately 18% of the lot area. <br />Setbacks: The B-1 District requires setbacks as provided below. <br />Proposed Required <br />Front 75 feet 35 feet <br />Side 130 feet 10 feet <br />Rear 35 feet 35 feet <br />Abutting Residential 35 feet 35 feet <br />Parking/Maneuvering (ROW) 20 feet 20 feet <br />Parking/Maneuvering (residential) 35 feet 15feet <br />It appears that a majority of the required setbacks are met with the proposed site plan. However, the <br />required setback for parking and maneuvering areas when abutting residential areas is deficient. Given <br />the tight spacing in the rear of the proposed lot, Staff encourages amending the rear property line to <br />increase the size of the proposed lot, thus increasing the amount of green space provided to the proposed <br />assisted living/memory care facility. This could be done for all, or a small portion of the rear property <br />line. The fire access land is exempt from this setback. Alternatively, the Applicant could request that a <br />variance be processed to account for the deficiency. <br />Exterior Materials. All exterior wall finishes on the proposed building shall be face brick, stucco, glass, <br />wood, natural stone, or specifically designed pre -cast concrete units whose surfaces have been integrally <br />treated with an applied decorative material or texture. The City may approve other materials and <br />combinations of materials are encouraged. It appears that there is a mixture of shakes, stone, and glass <br />with various accents proposed. It is unclear based on the Plans the specific materials to be used. Prior to <br />review by the Planning Commission and City Council, please provide City Staff with a list of materials to <br />be used. If the City is asked to approve other materials other than those listed above, specific City <br />Council will need to be granted. <br />Waste Storage: The waste storage area is proposed to be contained within the proposed building. <br />Off -Street Parking - Spaces Required: The B-1 District sets a minimum parking space standard of one <br />(1) space per four (4) hospital beds plus an additional space for each employee. The site plan proposed 66 <br />off-street parking spaces with space for an additional 28 spaces. It appears that there is ample parking for <br />this type of use. Please provide the City with the number of employees for final verification of parking <br />requirements. <br />