My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 10/16/2012 - Special
Ramsey
>
Public
>
Agendas
>
Council
>
2012
>
Agenda - Council - 10/16/2012 - Special
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2025 12:24:44 PM
Creation date
10/19/2012 11:43:41 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Title
Special
Document Date
10/16/2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Review File: Super America <br />Site Plan Review <br />September 28, 2012 <br />Revised October 12, 2012 <br />Page 5 of 7 <br />feet and a maximum height of four and a half (4.5) feet to meet the forty percent (40%) threshold. The <br />revised plans indicate that the attached car wash will be twenty-seven and a half (27.5) feet from the <br />northern property boundary (Parkway street designation). The site will also include a combination of <br />decorative fencing (Ameristar Echelon Series four [4] feet tall) and shrubs to create the required street <br />edge. Calculations were provided that verify the combination of decorative fencing and shrubbery <br />exceeds the required forty percent (40%) street frontage threshold. The proposed building location is <br />generally consistent with Development Plan 6. 1, which the City's Housing and Redevelopment Authority <br />has approved and will be considered by the City Council as part of the Design Framework ordinance <br />amendment on October 23, 2012. <br />Exterior Materials. The application includes two (2) sheets of architectural elevations, Sheet A3 <br />(building elevations) and Sheet CAI (canopy elevations). The exterior finish of the building appears to <br />consist of face brick, brick accent bands, clear tempered glass and dark bronze metal panels. The exterior <br />finish of the columns supporting the overhead canopy for the fueling islands appear to match that of the <br />principal building including face brick and brink accent bands. <br />Waste Storage: The waste storage area is proposed to be contained in an enclosure near the northwest <br />corner of the building. Exterior materials should be complimentary and consistent with the proposed <br />building. The exterior materials appear to be consistent with the exterior of the building and include a <br />wood composite gate for access. It appears that the western two (2) parking stalls may block access to the <br />waste enclosure; however, based on the September 28, 2012 responses to the Staff Review Letter, to <br />ensure access to the waste enclosure, these two (2) stalls will be `coned off during scheduled waste <br />removal pick-ups. <br />Off -Street Parking - Spaces Required: The COR -2 Commercial Sub -District sets a minimum parking <br />space standard of two (2) spaces per 1,000 square feet and a maximum of four (4) spaces per 1,000 square <br />feet for retail uses. The site plan proposes twelve (12) off-street parking spaces, which complies with the <br />parking standards within the Design Framework. <br />Signs: Please note that all signs for the proposed building must be approved through a separate sign <br />permit process. Sign regulations can be found within the Design Framework as well as in City Code <br />Chapter 117, Article II, Division 8. The developer is encouraged to review these sign regulations early in <br />the process to avoid any unnecessary delays due to potential needs for special permits. No dimensions are <br />provided for any of the proposed signs and thus, only general feedback is possible at this time, which <br />includes the following: <br />• Dynamic display signs are limited to no more than thirty-five percent (3501o) of the proposed <br />signage. However, the City is considering an amendment to this specific provision. Your <br />feedback is appreciated on a size of dynamic display that is desirable for your needs. <br />• Additional information must be provided regarding the LED accent lighting. Any bulb emitting <br />greater than 3,000 lumens (150) watts must be directed such that the bulb is not visible from off <br />the property where such light source is located. <br />
The URL can be used to link to this page
Your browser does not support the video tag.