My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 05/24/2016
Ramsey
>
Public
>
Agendas
>
Council
>
2016
>
Agenda - Council - 05/24/2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 3:49:53 PM
Creation date
5/25/2016 9:11:13 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
05/24/2016
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
610
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Review File: Brookfield 7th Addition <br />Final Plat <br />Engineering Review <br />May 18, 2016 <br />Page 2 of 2 <br />1. Generally Ramsey Details are shown. The details must be updated to the current versions. <br />The current versions were approved/ revised in 2016. The details can be downloaded from <br />the City website. <br />SWPPP Sheets: We offer the following comments on these sheets: <br />1. The text must be revised to change the Engineering Company Name in all locations. <br />2. The training credentials of all persons responsible for the SWPPP must be added to the <br />plan sheets or specifications. A copy of the card issued by the University of Minnesota is <br />sufficient. <br />Plat Sheet <br />1. This plan will be reviewed by the Anoka County Surveyor. <br />Stormwater Calculations <br />1. The stormwater summary indicates the basin in Block 3 provides adequate infiltration <br />volume for the impervious areas on this site. The 2 year runoff to this pond is only 30% <br />of the volume retained. This basin as designed does not provide the necessary volume <br />reduction. The storm sewer system must be revised to direct adequate flow to this basin to <br />meet the infiltration requirements. <br />2. The Hydrocad model appears to be an update of the previous model prepared for the master <br />development of Brookfield. The names of the subcatchments and ponds in this phase must <br />be updated to match the current block numbers. The proposed drainage map must be <br />revised to screen the contours and emphasize the drainage area boundaries, ponds and <br />storm sewers. These revisions must be done, some additional labels were added; <br />however. the storm water elan is not clear. <br />3. The summary must include a table comparing existing and proposed flows at the point <br />where stormwater leaves the Brookfield development. <br />4. The permit application shall not be submitted to the Lower Rum River Watershed <br />Management Organization until the City has provided comments on the stormwater plans. <br />Specifications <br />1. Add the necessary SWPPP training credentials. <br />Permits <br />Provide the City with a copy of the Construction Stormwater Permit Coverage Card. A <br />copy of the erosion control inspection logs must be provided to the City prior to closing <br />out the letter of credit for the project. <br />We do not have copies of the watermain and sanitary sewer extension permits. Please <br />provide information on the status of these permits. <br />Please make the necessary revisions and submit new sheets. <br />
The URL can be used to link to this page
Your browser does not support the video tag.