My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 10/10/1978 - Continuation of the 09/25/78 CC Mtg.
Ramsey
>
Public
>
Agendas
>
Council
>
1978
>
Agenda - Council - 10/10/1978 - Continuation of the 09/25/78 CC Mtg.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2025 2:55:34 PM
Creation date
8/10/2004 8:33:19 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Title
Continuation of the 09/25/78 CC Mtg.
Document Date
10/10/1978
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. Minimum exit door opening size 3/0 x 6/8 - Exit door opening from Assembly <br /> area, Exit doors to garage and from garage undersize. (UBC Sec. 3303(d)). <br /> 5. Doors must swing In direction of exit travel. (UBC Sec. 3303(b))o <br /> 6. Exits may not pass through kltchens or garages. (UBC Sec. 3302(e)). <br /> 7. Exit Corridors must be I hour fire resistive. (UBC Sec.3304(g)).with open- <br /> Ings proi'ected for a 20 minute time period (UBC Sec. 3304(h)). <br />8. Exit stair front door has Irregular risers (sldwalk setting). Verify rls~ <br /> and run of stalr In garage. (UBC Sec. 3305(c)). <br />9. Exit sign required. (UBC Sec. 3312). - <br />t0. Guard rail on exterior balcony must be 42" high, with max spacing of guard <br /> rail members so a 9" object cannot pass through. (UBC Sec..1716). <br />I!. Provide parking area for physically handicapped persons, ramped access, and <br /> sanitation facilities accessible ~nd usable by them. (SFM 501-568)." <br />12. Verify if glazing in patio doors Is Safety Glazing (UBC Sec. 5406). <br />13. Verify adequacy of sewage disposal system and water supply. <br />14. Ventllation of assembly area Inadequate UBC Sec. 705. Inadequate supply and <br /> return air ducts provided for assembly area (SBC 7504). <br />15. Plumbing fixtures (water closets) are designed for residential use and do npt <br /> comply with Minnesota Plumbing Code (MHD 127(d) 2) <br /> <br />One hour rated walls must be constructed with the fire resistive m~terial'applled <br />to both sides of the supporting members. See Table 43-B - Item 76. <br /> <br />If we may be of fubther assistance please contact this office. <br /> <br />· Yours very truly, <br /> <br />Sivert Hendr~ckson/Consu I tant <br />Building Code Division <br /> <br />SH/jc <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.