My WebLink
|
Help
|
About
|
Sign Out
Home
09/05/78
Ramsey
>
Public
>
Dissolved Boards/Commissions/Committees
>
Planning and Zoning
>
Agendas
>
1970's
>
1978
>
09/05/78
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2025 4:05:32 PM
Creation date
8/26/2004 7:57:00 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Document Title
Planning & Zoning Commission
Document Date
09/05/1978
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. Minimum exit door opening size 3/0 x 6/8 - Exit door opening from Assembly <br /> area, Exit doors to garage and from garage undersize. (UBC Sec. 3303(d)). <br /> 5. Doors must swing in dlrection of exit travel. (UBS Sec. 3303(b)). <br />6. Exits may not pass through kitchens or garages. (UBS Sec. 3302(e)). <br />7. Exit Corridors must be I hour fire resistive. (UBC Sec.3304(g))~with open- <br /> ings protected for a 20 minute time period (UBS Sec. 3304(h)). <br />8. Exit stair front door has irregular risers (sidwalk setting). Verify rise <br /> and run of stair In garage. (UBS Sec. 3305(c)). <br />9. Exit sign required. (UBS Sec. 3312). <br />I0. Guard rail on exterior balcony must be 42" high, with max spacing of guard <br /> rail members so a 9" object cannot pass through. (UBS Sec. I716). <br />II. Provide parking area for physically handicapped persons, ramped access, and <br /> sanitation facilities accessible and usable by them. (SFM 501-568).~ <br />12. Verify if glazing in patio doors is Safety Glazing (UBS Sec. 5406). <br />13. Verify adequacy of sewage disposal system and water supply. <br />14. Ventilation of assembly area inadequate UBS Sec. 705. Inadequate supply and <br /> return air ducts provided for assembly area (SBS 7504). <br />15. Plumbing fixtures (water closets) are designed for residential use and do npt <br /> comply with Minnesota Plumbing Code (MHD 127(d) 2) <br /> <br />One hour rated walls must be constructed with the fire resistive material~applied <br />to both sides of the~supporting members. See Table 43-B - Item 76. <br /> <br />If we may be of further assistance please contact this office. <br /> <br />Yours very truly, <br /> <br />S i vert Hend r'i ckson/Consu I tant <br />Building Code Division <br /> <br />SH/jc <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.