Laserfiche WebLink
Sec. 3205(c) - The last paragraph and exception is deleted. <br /> <br />Se.c 3207(c) - The amendment is carried forward which requires that roof over <br />flow drains, when provided, discharge above grade. <br /> <br />Sec. 3303 - Is amended to require at least on a entry door of dwelling units <br />or guest rooms leased for gain be a minimum of 3/0 x 6/8. <br /> <br />Sec. 3304(h) - Exception 2 relating to corridors of B-2 Occupancies is carried <br />forward. <br /> <br />Sec. 3305(j) - Provides that handrails are not required on private stairs with <br />less than 3 ri~ers. <br /> <br />Sec. 3319(b) - Is amended to clarify that those exit doors through which <br />patients are transported on stretchers or beds (not wheel-chairs) have a clear <br />opening width of 44". <br /> <br />Sec. 3319(c) - is amended to permit~corridors that are 6' wide for Group I <br />Div. 2 Occupancies. <br /> <br />Table 33A - Amendment is carried-'forward-deleting the last column. <br /> <br />Sec. 3082(e) - Amendment is carried forward to require fire extinguishing <br />systems in range hoods over commercial.-cooking equipment. <br /> <br />Sec. 3803(a) - Amendment revises UBC Standard 38-3 requiring an approved <br />source of water for all standpipes with the provision for acceptance of dry <br />standpipes by the fire chief. <br /> <br />Table 38A - Is revised to not require first aid standpipes (Class II) for <br />educational (E) & residential (R-i) Occupancies. <br /> <br />Sec. 4701(a) - Amendment is carried ~forward-referencing~ANSI~Standards~for <br />lathing, plastering, & stucco application. <br /> <br />Sections 5001 through 5006 are deleted. <br /> <br />Sec. 5101 through 5104 are deleted & reference made to 2MCAR Sec. 1.18801 <br />through Sec. 1.18806. <br /> <br />Sec. 6001 - Amendment references 1977 Edition of National Design Specification <br />for Wood Construction and the 1978 TPI Design Specification for Metal Plate <br />Connected Wood Trusses. <br /> <br />2MCAR Sec. 1.10301 through Sec. 1.10335 - Minnesota Prefabricated Structures & <br />Manufactured Building Code has been revised considerably to refine the process <br />of application~ acceptance & performance of 3rd party inspection agencies and <br />approval of manufacturing facilities and quality control programs. Fee <br />schedule has been revised upward. Identification of manufacturer readily <br />visible from exterior is required on all transportable units. <br /> <br />2MCAR 1.18601 - National Electrical Code Table 2002-2(b) has been amended to <br />reduce the minimum unit load to 3 watts per sq. ft. for office buildings & <br />banks. <br /> <br />4 of 6 <br /> <br /> <br />