My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 06/27/2017
Ramsey
>
Public
>
Agendas
>
Council
>
2017
>
Agenda - Council - 06/27/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 3:33:55 PM
Creation date
7/11/2017 8:03:38 AM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
06/27/2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1054
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 2641 —STANDARD SPECIFICATIONS FOR <br />PIPELINE REHABILITATION BY PIPE BURSTING <br />2641.1 DESCRIPTION <br />A General <br />All references to MnDOT Specifications shall mean the latest published edition of the Minnesota <br />Department of Transportation "Standard Specifications for Construction", and all supplements <br />and amendments thereto, published prior to the date of advertisement for bids. <br />This specification shall cover the rehabilitation of existing gravity and pressure utility pipelines <br />using pipe bursting methods. Pipe bursting is a process by which the bursting unit fractures the <br />existing pipe while simultaneously installing a new pipe of the same size or larger size pipe in <br />the place of the existing pipe. Existing lateral and service connections are disconnected prior to <br />mainline pipe bursting to reduce lateral pipe/service pipe damage, then reconnected after <br />testing and disinfection of the new pipe as applicable is approved, television inspection of the <br />new pipe is performed, and the installation is completed in accordance with the contract <br />documents. <br />2641.2 QUALIFICATIONS <br />The Contractor shall be certified by the particular Pipe Bursting System Manufacturer as a fully <br />trained installer of the pipe bursting system. The Contractor shall provide certifications of <br />training and proficiency in the use of the equipment. Only the Contractor's employees that are <br />trained and certified shall operate the equipment. <br />The Contractor shall have a minimum of five (5) years' experience using the pipe -bursting <br />method proposed and shall have installed no less than 50,000 feet by this method. <br />2641.3 MATERIALS <br />Pipe materials meet the requirements described in Sections 2611.2 and 2621.2 of these <br />specifications, and as provided in the Special Provisions and the following: <br />1. Sizes of the new pipe insertions shall be such to renew the pipe mainline to greater than <br />the original flow capacity. <br />2. All pipe and fittings shall be made of virgin material. No rework except that obtained <br />from the manufacturer's own production of the same formulation shall be used. <br />3. The pipe shall be homogenous throughout and shall be free of visible cracks, holes, <br />foreign material, blisters, or other deleterious faults. <br />4. Tensile strength of the pipe shall be in accordance with manufacturer's recommendation <br />for the specified purpose and method of installation. <br />5. Material color shall be as specified with interior of pipe having a light reflective color to <br />allow for viewing for television inspection. The fused pipe joints shall be de -beaded to <br />reduce collection of sediment and allow a camera to pass during inspection. <br />Page 69 <br />
The URL can be used to link to this page
Your browser does not support the video tag.