Laserfiche WebLink
SPECIAL PROVISIONS - SP20I6 BOOK <br />Last Revision by CO Special Provisions: 2/08/17 <br />Created August 20, 2015 <br />Page 56 <br />SP 0202-101 <br />Contractor shall drill and grout 2 No. 4 x 12 inch long reinforcement bars (Epoxy coated). Reinforcement bars <br />shall be placed a minimum of 3 inches from face and back of gutter section. When not accounted for in the Plan, <br />payment for these bars will be made under Item 2301.602 (Drill & Grout Reinforcement Bar (Epoxy Coated)) by the <br />Each at the Predetermined Price of $ 10.00 per bar furnished and installed. <br />The Contractor must form, at a minimum, the top 1.5 inches of the gutter face. The Contractor <br />shall not use the existing roadway edge as a form for the top 1.5 inches of the gutter face unless approved by the <br />Engineer. <br />If the gutter flow line in front of the proposed curb ramps exceeds 2.0% slope, the flow line should <br />be adjusted to allow a flatter slope in front of the curb ramps, but still provide positive drainage. The bituminous <br />patch in front of the truncated domes must not exceed 5% measured perpendicular to the flow line. In no case <br />shall a newly constructed curb and gutter flow line exceed 8% unless the roadway profile exceeds 8%. <br />The Contractor shall not alter any existing drainage patterns unless called for in the plans or <br />approved by the Engineer. <br />The Contractor shall construct a contraction joint through the curb and gutter section at the bottom <br />of the curb height transitions where the curb height equals zero inches. If any curb and gutter joints fall within the <br />PAR, they shall meet MnDOT 2521.3C. <br />When constructing directional curb where truncated domes are placed perpendicular to the path of <br />travel, the concrete between the grade break/edge of truncated domes and the gutter toe shall be constructed integral. <br />S-44.2 METHOD OF MEASUREMENT <br />Measurement of Concrete Curb and Gutter will be by the linear foot measured at the face of the <br />curb. <br />S-44.3 BASIS OF PAYMENT <br />Payment will be made under Item 2531.603 (Concrete Curb and Gutter) at the Contract bid price <br />per linear foot, which shall be compensation in full for all costs of furnishing and installing the required material <br />including Aggregate Base. <br />S-45 (2531) TRUNCATED DOMES <br />This work consists of furnishing and installing Truncated Dome Systems (detectable warning <br />surfaces) at pedestrian curb ramps in compliance with the Public Rights -of -Way Accessibility Guidelines <br />(PROWAG). This work shall be performed in accordance with the applicable MnDOT Standard Specifications, these <br />Special Provisions, the details in the Plan, and the following: <br />S-45.1 CONSTRUCTION REOUIREMENTS <br />The Contractor shall select a truncated dome product from the approved products list at <br />http://www.dot.state.mn.us/products/miscmaterials/truncateddomes.html. The truncated domes shall be placed in <br />concrete and shall be pressed firmly into the concrete to the point that concrete fills the vent holes on the truncated <br />dome plates. No cutting of truncated domes will be allowed unless approved by the Engineer. Any swelling of the <br />concrete that occurs around the truncated domes must be screeded off and the surrounding concrete shall be finished <br />flush with the truncated dome plate edge. To ensure that the truncated domes are well seated in concrete, the <br />Contractor should provide a 3 inch minimum border around the edges of the truncated domes. <br />The Contractor will be allowed to interchange 9 foot 5 inch and 10 foot radial truncated domes <br />when either is called for in the Plan. If the Contractor does make a substitution, the Contractor will be required to <br />modify the curb line radius to match the truncated domes and meet the detectable edge requirements shown on <br />Standard Plan Sheet No. 5-297.250 (Sheet 4 of 5). The Contractor will be allowed to adjust plan locations of zero <br />inch height curb up to 6 inches laterally to make field fit adjustments for radial truncated domes placement. <br />