My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 09/07/2006
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2006
>
Agenda - Planning Commission - 09/07/2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:40:19 AM
Creation date
9/1/2006 3:11:23 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
09/07/2006
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
173
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />. Planting depth shall be such that the trunk flare is at grade level. Trees planted <br />too deeply will be rejected. <br />. At installation, do not prune any branches unless they are broken or deformed (do <br />NOT prune 1/3 of foliage as shown in the tree planting detail). <br />. Any piuning cuts that are necessary shall be madejust outside the branch collar, <br />NOT flush with bark. <br /> <br />Please submit a revised plan that addresses these matters. <br /> <br />Tree Preservation: There are no areas of significant trees. Therefore, no tree <br />preservation plan is necessary ~ <br /> <br />Drainage and Grading: The following comments are offered regarding the drainage and <br />grading plan dated 8/15/06: <br />. NW comer of parking lot shows to he a low area (check grades) , <br />. Check grading plan-- area has been graded and many of the monitoring wells <br />shown on the plan have been removed. . <br />. Outlot A has T of fall in 150' -show how area will be maintained for erosion. <br />. Outlot A is private property and needs a construction permit from owner. <br />. Monitoring wells that remain need to have bollards placed around them with an <br />easement. Check with the MPCA for any grading around them and inquire if they <br />will need to be fenced off as well. <br />. Modular block retaining wall needs top and bottom elevation at beginning, <br />. middle, and end of wall. If wall is 42" high or more, it will need a fence along the <br />top. <br />. Drainage and utility easement will be required around the holding pond. <br />. An NPDS II permit is needed <br />. Lower FES in proposed pond to 870.00 <br />. Need storm casting detail for traffic areas <br />. All DIP watermains smaller than 6" must be class 53. <br />. What type of erosion control fabric is under the FES? <br />. Erosion control plan-- need to have a sweeper on site or get one within 3 hours. <br />. Storm catch basin will be required to have erosion control device installed in them <br />until vegetation has been established. <br />. The Weir detail show an .elevation of 977.54 to what? <br />. Stormwater calculation must be submitted to the Lower Rum River Water <br />Management Organization (LRR WMO) for review and approval. A permit must <br />be obtained from the LRRWMO. <br /> <br />Please submit a revised plan that addresses these matt~rs: <br /> <br />Access: The proposed site plan shows one access point on Azurite St. on th~ southwest <br />side of the property. This access point is sufficient to meet standards. Staff recommends <br />relocating access onto future 144tl1 Ave. upon completion of that street. <br /> <br />47 <br />
The URL can be used to link to this page
Your browser does not support the video tag.