My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Council - 02/25/2003
Ramsey
>
Public
>
Agendas
>
Council
>
2003
>
Agenda - Council - 02/25/2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:45:42 PM
Creation date
6/23/2003 12:04:01 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Council
Document Date
02/25/2003
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
282
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Preliminary Plat: The Village of Sunfish Lake <br />January 31,2003, Revised February 21, 2003 <br />Page 4 of 7 <br /> It should be noted that the designed overflow elevation could be reduced to elevation 863.17 <br /> if an overflow from Sunfish Lake to Wetland 1 I4P were provided as a condition to this <br /> development. This would reduce the requirement to accommodate a single 100-year event. <br /> <br />Similar to the northern drainage area, the backyards between Streets A and. ~3 will need to be <br />evaluated to determine the levels of 100 year ponding'. The comments above are based on <br />the calculations submitted by the developer. It should be noted that staff has not completed a <br />comprehensive review of these hydraulic calculations. <br /> <br />-218- <br /> <br />All wetlands within the site need to be identified and delineated and dedicated on the final <br />plat. as drainage and utility easements. Any wetland filling or mitigation will require permit <br />action by the Lower Rum Pdver Water Management Organization. <br /> <br />A permit from the Lower Rum River. Watershed Management Organization. and-the <br />Minnesota Pollution Control Agency will be required for drainage, The developer is <br />.responsible for obtaining any and alt permits required from other regulatory-agencies. <br /> <br />The City has enacted an ordinance that requires an elevation survey at the time of footing <br />inspection to ensure compliance with the approved grading plan. No grades shall be flatter <br />than 1%. Grades flatter than 2% will require a certificate of grading prior to an occupancy <br />permit being granted. <br /> <br />Staff has noted the following items on the grading and- drainage plan should be corrected <br />and/or addressed: <br /> <br /> · Where drainage is tntended to flow from rear of house pad to street (i.e. Lot 11, Block I), <br /> front comer lot elevations must provide for a minimum of 1% grade over turfed areas. <br /> · The high point on the north end of Street E must be identified <br /> · The.high points along Street A must be identified <br /> · The rear yard grades of Lots 1 and 2, Block 14 is flatter than 1%, which is contrary to <br /> City regulations and must be corrected. <br /> · Spec/fy emergency overflow for north pond. <br /> · Soil borings must be provided documenting the groundwater elevations. <br /> · Topographic information for a d/stance of 100 feet beyond the bo~Zders of the plat should <br /> be added to the plan. <br /> · Invert elevations and pipe sizes need to be added to the plan. <br /> · Drainage calculations need to be provided for the 10 year storm events. <br /> The development plan needs to identify the minimum floor elevations. <br />.:?~.ii:~A table must be submitted specif-ying house type, garage elevation, minimum floor <br /> elevation, lowest opening elevation, I00 year flood elevation,, and backyard and front <br /> yard slopes <br /> <br />11.. Easements. The standard 10 foot drainage and utility easements (5 feet on common property <br /> lines) must be provided around the perimeter of all lots on the preliminary and final plats. <br /> All wetlands located on the property must be delineated and dedicated as drainage easements. <br /> All utilities' are to be protected with a minimum 20 foot drainage and utility easement. This. <br /> <br />I <br />I <br />I <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.