My WebLink
|
Help
|
About
|
Sign Out
Home
Agenda - Planning Commission - 11/01/2007
Ramsey
>
Public
>
Agendas
>
Planning Commission
>
2007
>
Agenda - Planning Commission - 11/01/2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:42:22 AM
Creation date
10/26/2007 3:05:29 PM
Metadata
Fields
Template:
Meetings
Meeting Document Type
Agenda
Meeting Type
Planning Commission
Document Date
11/01/2007
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />adequate "truck traffic movements without impacts to the public right-of-way. Also, please <br />clarify what is anticipated when the future proof of parking along Azurite St. is constructed; <br />it appears that the easterly access point Will be eliminated with the installation of curb and <br />gutter. A request for comments has been" submitted to Anoka County. <br /> <br />. Utilities and Easements: The facility will be served by municipal sewer and water facilities <br />existing under Azurite Street. There is a 10. foot drainage and. utility easement proposed <br />around the interior perimeter of both lots. Additionally, there is an existing drainage pond on <br />Lot 2 that is encumbered with "drainage and utility easements. Please show the existing <br />MPCA stOrm sewer lIDe and any associated easements\ that encumber the site; this line is <br />sl10wn on the record drawings for project 01-32. Any additional easements must be <br />incorporated into the plat. Insulation must be added at the storm sewer and watermain <br />crossing if adequate separation cannot be achieved. Notes should be added to the plans <br />describing the connec~on to the existing watermain as no 90 degree bends are allowed. The <br />watermain extension to lot 1 will serve as that parcels service and must be isolated from the <br />service for lot 2 with appropriate valves. This 8" watermain shoul~ also be reduced, <br />consistent with the hydrant detail, to a 6" line and gatevalve. <br /> <br />Drainage and Grading: The proposed F~S from CBI\1H 1 into the stormwater pond is too <br />close to the existing outlet and must be relocated to prevent short circuiting. All proposed <br />FES's ip.to the pond must have an invert within l' of the bottom. The proposed impacts <br />along the west pond" slope (grading, pipe work, etc.) must be. mitigated with appropriate <br />erosion. control practices and potential sediment clean out when completed. Add notes for <br />the proposed seed mix and stabilization practice for this pond slope. The emergency <br />overflow from the proposed low point CBMH must be reinforced to prevent e~cessive . <br />erosion along the pond slope. Please describe temporary drainage patterns for the northerly <br />area, without impacts to adjacent properties . and until such time that the future addition and <br />associated improvements are constructed. Note #3 on the grading plan is inconsistent with <br />the site plan information and should be corrected or eliminated. <br /> <br />Lighting: All exterior lighting on the site must be arranged in such a way to avoid <br />illumination of the public street. The submitted lighting plan conforms to City Code if the. <br />bulbs in the exterior light posts are not visible from surrounding properties. Lighting must be <br />incorporated to provide adequate illumination at the access points along Azurite Street for <br />traffic safety. <br /> <br />Off-Street Parking - Spaces Required: City Code requires one parking space for every <br />1,000 square feet of manufacturing space and one parking space for every 300 square feet of <br />office space within a development. Based on the submitted floor plan, the proposed site plan <br />indic!!tes the need for 69 required spaces. 67 spaces are shown on the site plan, with an <br />additional 33 spaces of "proof of parking" for the future expansion area. <br /> <br />Off-Street Parking - Desigm The site plan indicates. that the parking area will be blacktop <br />with. concrete curbs and gutters with one landscaped island within the p~king lot. One tree <br />for every ten spaces of parking is required to be planted that provide shade to parking lots. <br />Also, it is suggested that a pedestrian walkway be constructed from the western and southern <br />parking lots along the building to the front door. <br /> <br />62 <br />
The URL can be used to link to this page
Your browser does not support the video tag.